Weekend Special 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: Board70

NCS-Core Exam Dumps - Nutanix NCS Professional Questions and Answers

Question # 14

A consultant finishes creating a new ESXi cluster. The consultant connects to the nodes via laptop and a personal flat switch. The host/CVM network is on VLAN 23. The customer has the native VLAN on the ToR switches set to 23.

The customer wants to use LACP. Before placing the nodes on the customer network, the consultant tags VLAN 23 for each host and CVM. The consultant connects the nodes to the customer network and finds that they are unreachable.

What is causing this issue?

Options:

A.

The customer has LACP fallback enabled on switch ports.

B.

The hosts have not been migrated to a vSphere Distributed Switch.

C.

Under the vSwitch0 settings, the consultant did not select Route based on IP hash.

D.

The host and CVM are incorrectly configured.

Buy Now
Question # 15

What are the two most important prerequisites to be validated before the consultant goes onsite? (Choose two.)

Options:

A.

Complete the kickoff call and validate the BOM (Bill of Materials).

B.

Verify whether the servers have been racked by the customer.

C.

Validate whether the cluster questionnaire is complete and if the physical switch configurations are complete.

D.

Identify the point of contact who can provide networking details and switch port information after arriving onsite.

Buy Now
Question # 16

For several days, an administrator notices the following alerts:

• CVM NIC Speed Low Warning Alerts

• Warning Alerts of CVM NIC not performing at optimal speed

• CVM is disconnected from the network Critical Alert

• Network Visualization page shows excessive dropped packets on CVM/Host

Which steps should be taken to determine which problem should be addressed first?

Options:

A.

• Access the Hardware Page to verify resources are available

• Analyze ail CVM Speed Alerts in the Alerts/Events page

• Analyze output for the network and interface properties and connectivity issues

B.

• Verify Host/CVM connectivity on the Network Visualization page

• Use to verify the bridge and bond configuration

• Review alerts/events page for the CVM disconnected error

C.

• Review Alerts page for NIC speed alerts and alert timing

• Analyze the genesis.out log file for process failures

• Assess the NIC properties in the Network Visualization > Host Properties page

D.

• Restart networking services on the CVM

• Determine the current configuration of the affected CVM via output

• Access the Alerts/Events page for the CVM network connection failures

Buy Now
Question # 17

Refer to the exhibit.

On a four-node NX-3460 cluster, two 10G NiCs are connected to redundant Cisco ToR 5K switches as shown in the first exhibit Port On a four-node NX-3460 cluster, two 10G NICs are connected to redundant Cisco TOR Sk switches as shown in the fist exthibt. Port failover must be tested.

The network configuration output from the CVM is shown in the second exhibit. To test fallover, a shut command is executed on the switchport that connects the node to the 5k1 switch.

Refer to the exhibit.

Options:

A.

Active link is disconnected. Passive link takes over.

B.

Passive link is disconnected. Active link takes over.

C.

Active link takes over. HA Failover takes place.

D.

Passive link takes over. HA Failover takes place.

Buy Now
Question # 18

A consultant deploys a new ESXi-based Nutanix cluster and migrates a sphere deployment to the cluster, After completing the deployment, the customer states they are experiencing VM performance issues.

Upon observing logs and performance data, the consultant identified the following symptoms.

◦ Excessive read/write 1/Os on CVMs

◦ Excessive Motion of VMs

What is causing this issue?

Options:

A.

Sphere cluster DRS migration threshold is set to Conservative.

B.

DRS is in use and the cluster is configured to use Erasure Coding.

C.

DRS is in use and the cluster is configured to use Deduplication.

D.

Sphere cluster DRS migration threshold is set to Aggressive

Buy Now
Question # 19

A consultant is planning to use a flat switch for installation.

What is the network requirement for Foundation VM, CVM, Hypervisor, and IPMI

Options:

A.

Foundation VM, CVM, and Hypervisor must be on the same subnet. IPMI can be on a different subnet.

B.

CVM, Hypervisor, and IPMI must be on the same subnet. Foundation VM can be on a different subnet.

C.

Foundation VM and CVM must be on the same subnet. Hypervisor and IPMI can be on a different subnet.

D.

Foundation VM, CVM, and IPMI must be on the same subnet. Hypervisor can be on a different subnet.

Buy Now
Question # 20

Refer to the exhibits.

A consultant is trying to test port failover on the node shown in the first exhibit. A continuous ping test is performed to the host. The consultant shuts down one of the links, after which the host ping request times out. The consultant tries to troubleshoot the issue with the customer and sees the information shown in the second exhibit on their Cisco Switches:

What is causing the issue?

Options:

A.

There is a Native VLAN mismatch on the switchport.

B.

The wrong VLAN is tagged on the host.

C.

Bad SPF+ cables are on the active interface.

D.

PortFast is not enabled on the port connected to the host.

Buy Now
Question # 21

A consultant is running the Foundation VM using desktop virtualization software. No nodes are discovered.

What should the consultant verify first?

Options:

A.

NAT

B.

Host-only Adapter

C.

Bridged Adapter

D.

Internal Network

Buy Now
Question # 22

A consultant is unable to install virtualization software on a laptop.

Which two versions of Foundation can be used to resolve this issue? (Choose two.)

Options:

A.

Foundation VM

B.

Foundation Portable

C.

Foundation Central

D.

Foundation Applet

Buy Now
Question # 23

As a consultant concludes the project for deploying a new cluster, the customer expresses plans to repeat the process in-house for one of the company's dark site locations.

What three items can the consultant deliver in closing to help ensure customer's success in deploying and supporting Nutanix clusters?

Options:

A.

. Creating an account for access to Nutanix Support Portal

· External USB drive

. Offline NCC bundle

B.

· A trial license activation code for Prism Starter

. Creating an account for access to Nutanix Support Portal

. Guide for dark site deployments using Nutanix standards

C.

. Generating cluster licenses

. What are binaries and where can they be downloaded

. Creating an account for accessing the Nutanix Support Portal

D.

· External USB drive

. Access to Nutanix FTP

. Encrypted key required for accessing clusters

Buy Now
Exam Code: NCS-Core
Exam Name: Nutanix Certified Services Core Infrastructure Professional (NCS-Core 6.8)
Last Update: Feb 23, 2025
Questions: 309
NCS-Core pdf

NCS-Core PDF

$25.5  $84.99
NCS-Core Engine

NCS-Core Testing Engine

$28.5  $94.99
NCS-Core PDF + Engine

NCS-Core PDF + Testing Engine

$40.5  $134.99