Question # 34

Within a data center, if you have dual path connectivity between the primary entrance room and secondary entrance room, in addition to dual connectivity between these two rooms and the main distribution and secondary distribution areas, what tier level would this infrastructure design represent?

Options:

A.

Tier I

B.

Tier II

C.

Tier III

D.

Tier IV

E.

Tier V

Buy Now
Question # 35

If you are working on a physical security plan for a data center and focusing on building and access control, what layer of the plan would this relate to?

Options:

A.

Layer 1

B.

Layer 2

C.

Layer 3

D.

Layer 4

E.

Layer 5

Buy Now
Question # 36

A building has six floors plus a basement. Each floor is 929 sq m (10,000 sq ft) and has approximately 50 CATV outlets respectively. There is a single hardline trunk cable installed from the basement headend passing through the telecommunications room (TR) on each floor. In order to maintain the LEAST signal loss passing through each telecommunications room (TR) to the next telecommunications room (TR), what device should you specify for use within each telecommunications room (TR)?

Options:

A.

Splitter

B.

Directional coupler

C.

Multiport tap

D.

Combiner

Buy Now
Question # 37

Which of the following is NOT an example of a perimeter pathway?

Options:

A.

Furniture pathways

B.

Surface raceways

C.

Multi channel raceways

D.

Under carpet cabling

E.

Raceways integrated within walls

Buy Now
Question # 38

You have been asked to design a public safety microwave radio system for the city of Fairbanks, Alaska. The requirement for reliability, maximum throughput, and minimum interference by fog, rain, or heavy snow is critical. Which frequency will best suit the system's needs?

Options:

A.

2.4 GHz

B.

4.9 GHz

C.

6.0 GHz

D.

11.0 GHz

E.

19.0 GHz

Buy Now
Question # 39

When specifying telecommunications outlet boxes, all of the following should be considered EXCEPT:

Options:

A.

Outlet box shall be a minimum of 100 mm (4 in) x 100 mm (4 in) x 76 mm (3 in)

B.

Outlet boxes should be installed near an electric outlet at the same height

C.

Different outlet boxes have different support requirements

D.

Floor mounted telecom outlet boxes should be coordinated with furniture to minimize the potential trip hazard

E.

Outlet boxes must be of adequate size so that minimum cable bend radius requirements are not exceeded

Buy Now
Question # 40

You are designing a firestop system for a hospital with several floors that have isolation rooms. Air leakage control is important to ensure rooms are sealed and restrict the spread of disease. Which firestop test rating should you use to ensure air leakage compliance?

Options:

A.

F rating

B.

L rating

C.

T rating

D.

W rating

Buy Now
Question # 41

You are designing a 4.9 GHz microwave system that is using rectangular waveguide from the transceiver to the inside wall of the shelter and an antenna using elliptical waveguide from the antenna to the outside wall of the shelter. The antenna has been designed to be placed 200 ft up on a 250 ft tower. What device will you specify that will best interconnect the two different waveguides?

Options:

A.

Elliptical wave guide pass through

B.

Elliptical wave guide clamp

C.

Elliptical waveguide connector

D.

Elliptical waveguide flange

Buy Now
Question # 42

Vertical conduit masts (with approved service heads) are limited to drop-wire attachments of up to ________ lines.

Options:

A.

4

B.

6

C.

12

D.

25

Buy Now
Question # 43

You are placing an entrance cable between two buildings connected by a conduit 205.3 m (588 ft) in length. What would be the MAXIMUM length of unlisted OSP cable that could be used before you terminate the cable or transition it to a listed cable?

Options:

A.

185 m (607 ft)

B.

200 m (656 ft)

C.

209 m (686 ft)

D.

213 m (700 ft)

E.

216 m (708 ft)

Buy Now
Exam Code: RCDD-002
Exam Name: BICSI Registered Communications Distribution Designer - RCDD
Last Update: Feb 5, 2025
Questions: 361
RCDD-002 pdf

RCDD-002 PDF

$29.75  $84.99
RCDD-002 Engine

RCDD-002 Testing Engine

$33.25  $94.99
RCDD-002 PDF + Engine

RCDD-002 PDF + Testing Engine

$47.25  $134.99