Weekend Special 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: Board70

AD01 Exam Dumps - Blue Prism Developer Questions and Answers

Question # 4

Please Refer to the exhibits.

A Developer is getting an error at the Navigate stage that uses a dynamic input value to navigate the left menu links in the web-based application What can be done to fix the issue?

Options:

A.

Web Target Address' attribute should be checked for the element

B.

Web Path/X Path' attribute should have '= (Equal)' as the Match Type

C.

'Value' field of the Web Text attribute should be cleared

D.

Web Page Address' attribute should be unchecked for the element

Buy Now
Question # 5

There are multiple rows of conditions in the Properties window of the Wait Stage. Which of the following is TRUE?

Options:

A.

The Wait Stage will sequentially check each condition, it does not require all conditions to be met

B.

If all conditions are met before the TimeOut penrid expires, the process will continue

C.

If no conditions are met, an internal error will appear and terminate the process

D.

The Wait Stage will simultaneously check all conditions and follow the logic of whichever condition is met first

Buy Now
Question # 6

Consider the following process flow:

Decision JA" properties are:

Decision "B" properties are.

Decision "C" properties are

What will happen when the process runs?

Options:

A.

The flow will pass through calculation stage "A"

B.

The flow will pass through calculation stage "B"

C.

The flow will pass through calculation stage "C"

D.

An exception will be thrown

Buy Now
Question # 7

Which of the following statements regarding the use of Work Queues are correct? (select 2 responses)

Options:

A.

Control Room allows filtering of the displayed queue items using exact tags and by using wildcards

B.

Wildcards are not allowed in the Tag Fitter property of the Work Queues business object Get Next Item action

C.

Work Queue item Status can only be set to Completed or Exception

D.

Tags can be used allow flexibility in the order items are worked within a single Work Queue

Buy Now
Question # 8

Please refer to the exhibits

Under what TWO conditions will the process move to the 'Close Down' page directly from the Stop? Decision stage during runtime?

Options:

A.

The specified Stop time has passed

B.

'Request Stop received from Control Room

C.

Priority of the remaining Queue Items is 0

D.

All the Queue Items have been processed

E.

Immediate Stop' received from Control Room

Buy Now
Question # 9

Examine the following Process flow:

The 'Start Value' data item is a number data item with an initial value of 10 The 'End Value' data item is number data item with an initial value of 0.

The Multi Calc stage is configured as follows

After the page has been rurv what value will be assigned to the 'End Value* data item?

Options:

A.

The Internal Exception 'Failed to evaluate expression - Division by zero' will be thrown

B.

100

C.

-10

D.

no

E.

30

Buy Now
Question # 10

A process contains only 4 stages. Study the following process flow.

The data item New Date is a date data item with no initial value.

The calculation stage is configured as follows:

What will happen when you execute the Create Date stage?

Options:

A.

5 days will be added to today's date and the result stored in the New Date data item.

B.

1 month will be added to today's date and the result stored in the New Date data item.

C.

1 week will be added to today's date and the result stored in the New Date data item.

D.

The process will throw an exception as the New Date data item is null.

Buy Now
Question # 11

Please refer to the exhibits.

All Data Items are of Text Data Type

What is the output once all stages are executed?

Options:

A.

Recent Activity (or John – Orders: AR34675 Refunds: CAB30981

B.

Recent Activity (or 4320 – Orders: REF4399 Refunds: USD18.99

C.

Recent Activity for 4320 – Orders: AR34675 Refunds: CAB30981

D.

Recent Activity for John – Orders: REF4399 Refunds: USD18.99

Buy Now
Question # 12

A Blue Prism Process has been developed which contains steps to extract data from a delimited file.

During development, the Developer saves the delimited file to C:\BP_Proc\Temp folder on their virtual desktop and adds a data item to the process to store this file path. This data item is then used in the process steps to extract the file data.

The production Process must read this file from a network folder, and as the Blue Prism production environment is locked down, the Process configuration cannot be edited in this environment.

How could the data item ‘exposure’ be updated, so that the process can read the data item containing the relevant file path, regardless of the environment the process is being executed in?

Options:

A.

Update the data item exposure to 'Statistic'

B.

Update the data item exposure to 'Environment'

C.

Update the data item exposure to 'Session'

D.

Update the data item exposure to 'Shared'

Buy Now
Question # 13

The data item "Loop Counter" is a number data item and has an initial value of 0. The data item "Max Loops" is a number data item and has an initial value of 10.

The two stages are configured as follows:

How many times will the Loop Again stage be executed when the page is executed?

Options:

A.

10

B.

9

C.

11

D.

The loop will be infinite

Buy Now
Exam Code: AD01
Exam Name: Blue Prism Accredited Developer Exam
Last Update: Feb 23, 2025
Questions: 189
AD01 pdf

AD01 PDF

$25.5  $84.99
AD01 Engine

AD01 Testing Engine

$28.5  $94.99
AD01 PDF + Engine

AD01 PDF + Testing Engine

$40.5  $134.99