Weekend Special 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: Board70

AD01 Exam Dumps - Blue Prism Developer Questions and Answers

Question # 34

Please refer to the exhibits.

This is a detail of a Process sub-page

* Sign Up Dale Current Date and Expiry Date Dala Hems are of the Date data type

* Status and Output Data Items are of the Text' data type.

What is the output of this logic when the page is executed till its End stage'

Options:

A.

Subscription Status = Expired. Expiration Date = 04-07-2023

B.

Internal Error at the Decision stage as > function cannot be used for dates

C.

Internal Error at the Calc3 stage as a date cannot be stored in a Text Data Item

D.

Subscription Status = Active; Expiration Date = 04-07-2023

Buy Now
Question # 35

The Work Queue "Customer Onboarding' has a number of Pending Items which may be tagged as "Domestic", "Retail" or "Business" There is also a tag for the 8 digit product code formatted as "Product Code: {product code}" e.g. Product Code: CA123456.

What is the correct configuration to get the next item from the queue that:

• Isn't applying for a loan product i.e. Product Code doesn't begin with "LN"

And

• Is a domestic customer

Options:

A.

Configure "Domestic; -Product Code: I_N"" in the Tag Filter parameter

B.

Configure "Domestic; -Product Code: LN?" in the Tag Filter parameter

C.

Configure 'Domestic and Product Code <> LN?" in the Tag Filter parameter

D.

Configure "Domestic + [Product Code] <> LN*”” in the Tag Filter parameter

Buy Now
Question # 36

Consider the following process flow:

Decision "A" properties are:

Decision "B" properties are:

Decision "C" properties are:

What will happen when the process runs?

Options:

A.

The flow will pass through calculation stage "A"

B.

The flow will pass through calculation stage "B"

C.

The flow will pass through calculation stage "C"

D.

An exception will be thrown

Buy Now
Question # 37

Please refer to the exhibit

An automation Start Up page has been created to launch and login to the Blue Prism Portal. The page has no Input or Output Parameters The page is run but causes an Exception What is the cause?

Options:

A.

The Username and Password Data Items contains no hard-coded credentials

B.

The BP Portal. Go to LMS action should be inside the Login Block

C.

There is no action to retrieve the credentials from Credential Manager

D.

The BP Portal Launch action should have a retry loop

Buy Now
Question # 38

Please refer to the exhibits.

A Developer has created the logic that is resulting in an infinite loop of exceptions when the Multi Calc stage is executed

What is the reason"?

Options:

A.

The Exception functions are used outside the recovery mode resulting in their own exception

B.

A Block is not used for the Recovery stage causing it to catch Exceptions from all stages on the page

C.

An Exception stage is not used to report Exceptions causing an infinite loop in the recovery logic

D.

The Data Item names are the same as the Exception expression resulting in their own exception

Buy Now
Question # 39

Examine the following Blue Prism Process flow:

The Process is intended to attempt to perform the processing enclosed in the recover block (Blockl). a maximum number of times before throwing an exception The maximum number of attempts is stored in the 'Max Attempts' data item.

The 'Attempts' data item is a number data item with an initial value of 0.

The 'Max Attempts' data item is a number data item with a current value of 3. This value is provided at start-up.

The 'Increment Attempts' Calculation stage increases the value of the 'Attempts' data item by 1.

To enable this Process flow to function correctly, drag and drop the items below into the placement boxes (A - C), to create the correct Blue Prism expression for the Retry?' Decision stage.

Options:

Buy Now
Question # 40

An Action called ‘Get Customer Address’ fails immediately and the following Exception is raised:

Internal: Stage Address Type does not exist

What is the potential reason for this Exception?

Options:

A.

An Action stage with the name 'Address Type' is being referenced but it no longer exists

B.

An internal error always indicates a problem with the Blue Prism product. The Blue Prism support team should be contacted for assistance

C.

A data item referenced as an input parameter in the 'Get Customer Address' Action cannot be found

D.

Whilst debugging a Process in Process Studio, the 'Reset' button was pressed whilst the process was calling the 'Get Customer Address' action

Buy Now
Question # 41

If you change a session variable when will the new value be available to the process?

Options:

A.

Immediately

B.

Next time a new case is taken from a WQ

C.

Next time resource PC starts

D.

Next time the process starts

Buy Now
Question # 42

If you change the value of a 'Session Variable1, when will the new value be available to a running Process?

Options:

A.

Immediately

B.

Next time a new case is taken from a Work Queue

C.

Next time the Process starts

D.

After the Digital Worker has been restarted

Buy Now
Question # 43

Please refer to the exhibit

What is the missing phase in the Delivery Lifecycle?

Options:

A.

Plan

B.

Outline

C.

Develop

D.

Design

Buy Now
Exam Code: AD01
Exam Name: Blue Prism Accredited Developer Exam
Last Update: Feb 23, 2025
Questions: 189
AD01 pdf

AD01 PDF

$25.5  $84.99
AD01 Engine

AD01 Testing Engine

$28.5  $94.99
AD01 PDF + Engine

AD01 PDF + Testing Engine

$40.5  $134.99