An administrator wants to assign a storage policy to a workload on a two-node vSAN OSA cluster consisting of three disk groups each with nested fault domains. The virtual machine must be protected against a disk or disk group failure.
Which two storage policies meet these requirements? (Choose two.)
A vSAN administrator is planning to deploy a new vSAN cluster with these requirements:
Physical adapters share capacity among several traffic types
Guaranteed bandwidth for vSAN during bandwidth contention
Enhanced security
Which two actions should be taken to configure the new vSAN cluster to meet these requirements? (Choose two.)
An application refactor requires significant storage that is being added for logs stored on a VM vDISK. The application VMs run on a dedicated vSAN enabled vSphere Cluster with custom CPUs and RAM, and therefore, cannot vMotion to another vSAN enabled cluster.
The administrator needs a vSAN feature that can be used to allocate additional storage from another vSAN enabled vSphere cluster to this vSAN enabled Cluster.
Which vSAN feature should be used for this purpose?
What are two prerequisites for using the TRIM and UNMAP capability of vSAN? (Choose two.)
A vSAN administrator has a cluster configured with a Storage Pool that was moved to a new physical DC.
Upon checking on the vSAN cluster health status, one of the ESXi hosts has two storage devices in a degraded state and must be replaced.
What must the vSAN administrator do to restore the health of the vSAN cluster with minimum risk?
A vSAN administrator needs to update vSAN from version 7.0.2 to version 8.0.
Which is the correct order to perform the update?
vSAN requires that the virtual machines deployed on the vSAN datastores are assigned at least one storage policy, but the administrator did not explicitly assign a storage policy when provisioning the new VM.
What is the result of this situation?
How often does the Skyline Health interval validate online if there are new Health Checks available for vSAN?
All of the virtual machines running on a hybrid vSAN datastore have this storage policy assigned:
Failures to Tolerate (FTT) rule is set to "2 Failures - RAID-1 (Mirroring)"
The vSAN administrator needs to reduce the amount of vSAN datastore capacity the virtual machines will consume.
Which action should the vSAN administrator take to meet this goal?
An administrator has to perform maintenance on one of the hosts in a three-node vSAN Cluster.
Which maintenance mode option will give the administrator the best availability for the VMs with the least effort and data transfer?