Weekend Special 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: Board70

HPE0-V14 Exam Dumps - HPE ATP - Hybrid IT Solutions V2 Questions and Answers

Question # 4

A customer Has a data center with third-party routers and firewalls You are designing a new data center network switch architecture consisting of FlexFabric switching for the data network and ArubaOS-Switch switching for the out-of-band management network.

The customer needs a network management platform with the capabilities to manage and monitor the entire environment

Which management platform meets the customer requirements?

Options:

A.

Aruba Central

B.

HPE OneView

C.

HPE IMC

D.

Aruba Airwave

Buy Now
Question # 5

Read the question, and then refer to the exhibit.

display interface Ten-GigabitEthernet 1/0/1 Ten-GigabitEthernet1/0/1 Current state: Administratively DOWN Line protocol state: DOWN IP packet frame type: Ethernet II, hardware address: d894-03fb-793d Description: Ten-GigabitEthernet1/0/1 Interface Bandwidth: 10000000 kbps Loopback is not set Media type is stack wire, port hardware type is STACK_SFP_PLUS Unknown-speed mode, unknown-duplex mode Link speed type is autonegotiation, link duplex type is autonegotiation Flow-control is not enabled Maximum frame length: 10000 Allow jumbo frames to pass Broadcast max-ratio: 100% Multicast max-ratio: 100% Unicast max-ratio: 100% PVID: 1 MDI type: Automdix Port link-type: Trunk VLAN Passing: 10, 20 VLAN permitted: 10, 20 Trunk port encapsulation: IEEE 802.1q Port priority: 0 Last link flapping: 0 hours 0 minutes 18 seconds Last clearing of counters: Never Peak input rate: 78 bytes/sec, at 2011-03-31 04:55:57 Peak output rate: 15 bytes/sec, at 2011-03-30 23:00:57 Last 300 second input: 0 packets/sec 67 bytes/sec - % Last 300 second output: 0 packets/sec 14 bytes/sec - % Input (total): 62670 packets, 8565340 bytes 0 unicasts, 0 broadcasts, 62670 multicasts, 0 pauses Input (normal): 62670 packets, - bytes 0 unicasts, 0 broadcasts, 62670 multicasts, 0 pauses Input: 0 input errors, 0 runts, 0 giants, 0 throttles 0 CRC, 0 frame, - overruns, 0 aborts – ignored, - parity errors Output (total): 3707 packets, 1294835 bytes 0 unicasts, 0 broadcasts, 3707 multicasts, 0 pauses Output (normal): 3707 packets, - bytes 0 unicasts, 0 broadcasts, 3707 multicasts, 0 pauses Output: 0 output errors, - underruns, - buffer failures 0 aborts, 0 deferred, 0 collisions, 0 late collisions 0 lost carrier, - no carrier

A customer added a new switch to their network. They connected it using interface Ten-GigabitEthernet 1/0/1. They are using VLAN 10 and 20 for the devices in their network.

The new switch was fully operational. Then, the customer experienced a power failure later that day and could not reach any device on the new switch after the power returned.

From the output in the exhibit, would could be the issue?

Options:

A.

The interface loopback is not set.

B.

The interface link-speed and duplex are unknown.

C.

The interface is administratively down.

D.

The interface is configured for a PVID of VLAN 1.

Buy Now
Question # 6

A customer is moving a server from a co-location facility back into their existing data center to comply with new internal policies on data management

Due to budget constraints, the customer cannot purchase any additional switches and will need to use an existing end-of-row design with HPE FlexFabric switches While the server will be installed six racks away from the switches, the total cable run with cable management Is expected to be 35 m.

Which component should be selected when designing the 10 Gbps connectivity option for the server?

Options:

A.

QSFP28 Active Optical Cable

B.

SFP+ 10G LC SR Transceiver

C.

SFP+ Active Optical Cable

D.

SFP+ Direct Attach Copper Cable

E.

QSFP+ Active Optical Cable

Buy Now
Question # 7

Which backup targets are available from an HPE StoreOnce backup system? (Choose two.)

Options:

A.

VTL

B.

Catalyst

C.

NVMe

D.

S3

E.

iSCSI

Buy Now
Question # 8

A customer ordered a pair of HPE SN3000B 16 Gb Fibre Channel Switches to provide Fibre Channel connectivity between VMware ESXi hosts and HPE 3PAR StoreServ 8200.

Which adapter i s required to support Fibre Channel connectivity from the VMware ESXi hosts to the new switches?

Options:

A.

HBA

B.

SAS

C.

CNA

D.

NIC

Buy Now
Question # 9

A customer needs a server memory subsystem that meets the following requirements:

  • approaches the speed of traditional DRAM
  • ensures high capacity, high performance, and ongoing data safety in case of a power failure

Which HPE memory feature meets the customer needs?

Options:

A.

Load Reduced DIMMs

B.

Memory Mirroring

C.

Fast Fault Tolerance Memory

D.

Persistent Memory

Buy Now
Question # 10

You are installing an HPE ProLiant server in a rack at a customer site. The customer’s facility is in a high-voltage utility service area, and they want to be certain that the power supply is supported.

Which ProLiant feature addresses the customer’s concern?

Options:

A.

ProLiant servers can be configured for 380 – 400V AC in low-line and high-line utility service areas.

B.

ProLiant servers support 240 V DC power supplies because components in a direct current line are less prone to failure.

C.

Rack-mountable HPE servers ship with 110 V DC power supplies because direct current is less expensive for a low-line utility service over short distances.

D.

ProLiant servers include auto-sensing power supplies with a power input range of 100-240 VAC, so they can be used globally.

Buy Now
Question # 11

Refer to the exhibit.

The information shown is displayed for a Nimble array you are installing. The customer’s administrator has asked you for the speed at which the Nimble ports are connecting to their SAN switches, and you have run the command shown to determine the number of gigabits per second used by this port connection.

What speed does the exhibit indicate is in use?

Options:

A.

18

B.

32

C.

6

D.

8

Buy Now
Question # 12

A local state college is implementing a new VDI cluster to support computer and testing labs. They have the following requirements:

  • Three VMware ESXi Hosts, each with one AMD processor, 1 TB of RAM, 16 Gbps FC Dual Port HBA.
  • HPE Nimble AF20 with 17 TB usable capacity.
  • Integration into an existing HPE FlexFabric 5710 and HPE SN3000B Fibre Channel SAN switches.
  • The solution must fit in 7U of rack space. If the customer needs more capacity in the future, they will use scale-out growth.

Which server model should you recommend to this client?

Options:

A.

HPE DL385

B.

HPE DL380

C.

HPE DL360

D.

HPE DL325

Buy Now
Question # 13

Which HPE solution brings together CPU, Memory, and Disk with an unpredictable workload into a single management infrastructure?

Options:

A.

dHCI

B.

SimpliVity

C.

Nimble

D.

Primera

Buy Now
Exam Code: HPE0-V14
Exam Name: Building HPE Hybrid IT Solutions (Rev. 19.41)
Last Update: Feb 22, 2025
Questions: 303
HPE0-V14 pdf

HPE0-V14 PDF

$25.5  $84.99
HPE0-V14 Engine

HPE0-V14 Testing Engine

$28.5  $94.99
HPE0-V14 PDF + Engine

HPE0-V14 PDF + Testing Engine

$40.5  $134.99