Question # 4

If the UPS5000-E is overloaded in normal mode, it transfers to bypass mode immediately. The bypass supplies power to loads to protect the UPS.

Options:

A.

True

B.

False

Buy Now
Question # 5

Which of the following statements is true about UPS5000 power modules and bypass modules?

Options:

A.

The UPSS000-E-200K and UPS5000-E-400K use the same power module and provide the same capacity of 50 kVA but have different numbers of power modules.

B.

For UPSs of the same model but in different power segments, their bypass module capacity is the same.

C.

The power module capacity of both the UPS5000-S and UPS5000-E is 50 kVA. Therefore, the two types of UPS can be used together.

D.

The power modules used in the UPSS000-S-1200K are the same as those used in the UPS5000-E-200K.

Buy Now
Question # 6

Three UPS5000-E-400Ks from a 2+1 parallel system. Which of the following statements about the parallel system are true?

Options:

A.

The parallel system capacity displayed on the LCD is 1200 kVA.

B.

The networkingmode is set to one-to-multiple for one UPS, and set to one-to-one for the other two UPSs.

C.

If the load is 420 kW, each of two UPSs carries 210 kW load, and the other one is standby and does not carry load.

D.

If the load is 420 kW, each of the three UPSs carries 140kW load.

Buy Now
Question # 7

If the battery charge current limit coefficient of the UPS5000-E is set to 0.1C10, which of the following statements about this parameter is true?

Options:

A.

The maximum batten/ charge current is 0.1C10.

B.

The batten/ charge current is always 0.1C10.

C.

The battery float charge current is 0.1C10.

D.

The maximum battery charge current is 0.1C10.

Buy Now
Question # 8

What are the application scenarios of lead-acid batteries in Huawei FusionModule2000 standard configuration?

Options:

A.

Battery pack

B.

Built-in battery cabinet

C.

External battery rack

D.

Battery box

Buy Now
Question # 9

In the water-side free cooling solution, cold water cannot be transported directly from the cooling tower to chilled conditioner?

Options:

A.

True

B.

False

Buy Now
Question # 10

When installing a water-cooled module, what is the minimum distance between the module and the wall?

Options:

A.

300 mm

B.

400 mm

C.

500 mm

D.

600 mm

Buy Now
Question # 11

The ECC800-Pro is the core component for FusionModule2000 local management. Southbound components can be using the PoE bus.

Options:

A.

True

B.

False

Buy Now
Question # 12

For FusionModule2000, depending on different layout position, batteries can be deployed in the smart module or out of the smart module.

Options:

A.

True

B.

False

Buy Now
Question # 13

What are the benefits of PowerEcho for the NetEco?

Options:

A.

Web-based unified maintenance interface

B.

Operation wizard

C.

Quick fault locating

D.

One-click health check

Buy Now
Exam Code: H12-425_V2.0
Exam Name: HCIP-Data Center Facility Deployment V2.0
Last Update: Feb 22, 2025
Questions: 55
H12-425_V2.0 pdf

H12-425_V2.0 PDF

$25.5  $84.99
H12-425_V2.0 Engine

H12-425_V2.0 Testing Engine

$28.5  $94.99
H12-425_V2.0 PDF + Engine

H12-425_V2.0 PDF + Testing Engine

$40.5  $134.99