Winter Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: bigdisc65

Fire-Inspector-II Exam Dumps - International Code Council Fire Inspector Questions and Answers

Question # 14

A building occupied for aerosol storage shall be classified as which of the following occupancy classifications?

Options:

A.

High-hazard Group H

B.

High-hazard Group H-2

C.

High-hazard Group H-3

D.

Group S-1

Buy Now
Question # 15

Foamed plastics or materials containing foamed plastics used for stage scenery must be approved when tested in accordance with

Options:

A.

UL 1975

B.

NFPA 11A

C.

CPSC 16CFR

D.

ASTM D 1784

Buy Now
Question # 16

Given: A nonsprinklered building constructed with protected noncombustible material has a fire-resistive rating of a minimum of 1 hour. What is the most protective type of construction, from the choices below, that meets these parameters?

Options:

A.

IIA

B.

IIB

C.

IIIB

D.

VA

Buy Now
Question # 17

The interior finish of walls and a ceiling in an atrium may not be less than __ Class

Options:

A.

A

B.

B

C.

C

D.

D

Buy Now
Question # 18

A Type I handrail that is not circular shall have a minimum perimeter dimension of ___ inches.

Options:

A.

1.25

B.

2

C.

4

D.

6.25

Buy Now
Question # 19

The clearance requirement from structures for open burning may be reduced to a minimum of ___ ft. from a structure when the burning is conducted in an approved container.

Options:

A.

10

B.

15

C.

25

D.

50

Buy Now
Question # 20

What is the maximum number of students permitted in a classroom that measures 20 ft. x 30 ft., and which contains four fixed 4 ft. x 8 ft. tables?

Options:

A.

12

B.

24

C.

30

D.

40

Buy Now
Question # 21

Extra-high-rack combustible storage is defined in the fire code as any storage on racks of Class I, II, III, or IV commodities which exceed ___ ft. in height, and any storage on racks of high-hazard commodities which exceed ___ ft. in height.

Options:

A.

20; 30

B.

30; 40

C.

40; 30

D.

50; 40

Buy Now
Question # 22

Fire inspectors receiving citizen complaints about a building should first:

Options:

A.

record all pertinent information.

B.

investigate the history of the building.

C.

forward the complaint to the senior inspector.

D.

inform the owner of the building that a complaint has been filed against him.

Buy Now
Question # 23

The maximum quantity of liquefied petroleum gas (LP-gas) in containers stored by a dealer awaiting resale, and are at one location in a building that is not accessible to the public, is __ lb. water capacity.

Options:

A.

735

B.

1,000

C.

2,000

D.

2,500

Buy Now
Exam Code: Fire-Inspector-II
Exam Name: 67 - Fire Inspector II Exam
Last Update: Apr 17, 2025
Questions: 87
Fire-Inspector-II pdf

Fire-Inspector-II PDF

$29.75  $84.99
Fire-Inspector-II Engine

Fire-Inspector-II Testing Engine

$33.25  $94.99
Fire-Inspector-II PDF + Engine

Fire-Inspector-II PDF + Testing Engine

$47.25  $134.99