An engineer is implementing a storage area network where an NPV is used. The engineer notices that the servers in a storage farm are experiencing heavy traffic contention. The engineer needs to migrate traffic from heavily loaded server interfaces to interfaces with less load. When the new links are deployed, the existing traffic is not rebalanced as expected. Which feature must be used to meet these requirements?
A network design must include a solution to run CLI commands remotely on Cisco Nexus 9000 Series Switches. The customer's security policy requires secure login credentials and an encrypted underlying transport. The command output will be processed using tools that support XML or JSON encoding. Which two components should be included in the design? (Choose two.)
Refer to the exhibit. An engineer working for a service provider with an employee ID: 4800:35-849 must perform the mapping of Fibre Channel LUN targets lo the indicated iSCSI virtual target. Which configuration shows the requited mapping?
A network consultant evaluates the Ethernet Adapter Policy configuration to be applied to the Cisco UCS blade servers. The policy must minimize latency and increase throughput for sensitive applications. The solution must increase the CPU data cache hit rate to meet these requirements Which policy is required?
A set of virtual machines must be live migrated from a data center to a disaster recovery site. The data center and disaster recovery sites are connected through an Inter-Pod Network topology. The gateway address of the virtual machine is the same across the data center and disaster recovery. Which Cisco Nexus feature supports this requirement?
Which two naming formats identify target or initiator iSCSI nodes? (Choose two.)
A customer needs a design for a new network VLANs must be dynamically provisioned based on the information received from connected hosts No Layer 2 or Layer 3 configuration must be performed on the related switch ports. Which feature must be used?
Refer to the exhibit. A Cisco engineer is configuring a PBR in a Cisco ACI data center scenario and plans to insert a transparent firewall. The APIC release is 4.1. the Cisco ACI fabric is configured to be the gateway for the servers and for the PBR node, and the Layer 4/ Layer 7 devices are deployed as Layer 1/ Layer 2 mode in the physical domain. Layer 1/Layer 2 PBR node interfaces arc also configured to be in a bridge domain and not in an L30ut. What is required for the consumer and provider connectors of the Layer 1/Layer 2 device for this scenario to work?
A network consultant evaluates the Cisco UCS Fabric Interconnect SAN configuration, which must meet these requirements:
All traffic must pass over the upstream device for switching and domain IDs must be preserved in the fabric.
Each server should be pinned to one designated upstream interface and for the traffic to pass through the pinned port.
Which Fabric Interconnect SAN operational mode meets these requirements?