Month End Special 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: Board70

DES-4122 Exam Dumps - EMC DCS-IE Questions and Answers

Question # 4

An engineer is checking a newly delivered Dell EMC PowerEdge R640 server that will be deployed for a new database environment

The inventory consists of:

The server power configuration will be set for gnd redundancy The management switch is 1000 Base-T and the top of rack switches 10Gb

What additional component(s) is needed for this configuration?

Options:

A.

Hot-plug power supply, 750 W - qty 1

B.

Hot-plug power supply, 1100W - qty 1

C.

Dell Networking, cable, 40GbE (QSFP+) to 4 x 10GbE SFP+ passive copper breakout cable, 3 meters - qty 2

D.

C20 to C21, PDU style, 250 V, 16 Amp, 3 5 meters power cord - qty 2

Buy Now
Question # 5

What is a key feature introduced in OpenManage Mobile v2.0?

Options:

A.

Access servers remotely through OME

B.

Access SupportAssist reports

C.

Access a Virtual Console (VNC over SSH) securely

D.

Access iDRAC remotely

Buy Now
Question # 6

An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU is in the Failed state.

What task should be completed to troubleshoot this issue?

Options:

A.

Confirm the System Input Power CAP is not set to Low

B.

Set the PSU AC redundancy to 1+1

C.

Set the PSU AC redundancy to 1+0

D.

Verify the new PSU is the same type and wattage rating

Buy Now
Question # 7

What is a systems management console solution optimized for monitoring and managing Dell enterprise and remote office hardware?

Options:

A.

SupportAssist Enterprise

B.

iSM

C.

OpenManage Essentials

D.

iDRAC9

Buy Now
Question # 8

What happened on April 30, 2019?

Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

Options:

A.

Option A

B.

Option B

C.

Option C

D.

Option D

Buy Now
Question # 9

For a temporary migration task the CPU core count on the Dell EMC PowerEdge R640 server needs to be reduced to 8 because the installed application will not work due to license restrictions. Use the simulator to apply the change so the application can be installed.

When you have finished using the simulator, click Next.

Options:

Buy Now
Question # 10

You are Investigating a disk error on a Dell EMC PowerEdge server and discover a Hot Spare has not been assigned to the Virtual Disk Group. Use the simulator to assign the Global Hot Spare. When you have finished using the simulator, dick Next.

Options:

Buy Now
Question # 11

A system engineer has a 14G Dell EMC Poweredge server with an amber light blinking. The engineer must pull a SupportAssist collection before calling Dell Support to evaluate what the potential problem. Use the simulator to collect and view the SupportAssist collection.

Options:

Buy Now
Question # 12

A technician wants to remotely log in to a server but finds that the IDRAC virtual Console feature Is not available. Use the simulator to explore the system. What Is the cause of this Issue?

Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

Options:

A.

The Virtual Console is disabled

B.

Operating system not installed on remote server

C.

The server has been powered down

D.

There are more than the maximum number of active sessions

Buy Now
Exam Code: DES-4122
Exam Name: Specialist - Implementation Engineer PowerEdge Version 2.0
Last Update: Jan 31, 2025
Questions: 60
DES-4122 pdf

DES-4122 PDF

$25.5  $84.99
DES-4122 Engine

DES-4122 Testing Engine

$28.5  $94.99
DES-4122 PDF + Engine

DES-4122 PDF + Testing Engine

$40.5  $134.99