Weekend Special 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: Board70

3V0-42.20 Exam Dumps - VMware VCAP-NV Design 2020 Questions and Answers

Question # 4

Which three choices are non-functional requirements? (Choose three.)

Options:

A.

authorization

B.

certification

C.

availability

D.

authentication

E.

scalability

F.

cost

Buy Now
Question # 5

An architect is helping an organization with the Physical Design of an NSX-T Data Center solution.This information was gathered during a workshop about ESXi Host networking:

  • A total of 50 ESXi hosts to be configured as Transport Nodes.
  • All ESXi hosts have a dedicated 2 × Intel 10Gbps Physical Network adapter for the Overlay Traffic.

To achieve low latency, high throughput, redundancy, and performance, which two NIC teaming policies should the architect recommend? (Choose two.)

Options:

A.

Load Balance Source MAC

B.

Load Balance Port ID

C.

Load Balance Source

D.

Load Balance Source Port ID

E.

Failover Order

Buy Now
Question # 6

A customer deploying NSX-T Data Center requires role based access controls be enforced in NSX Manager with these requirements:

  • identity platform must be highly available
  • authentication must be performed by customer’s existing SAML identity provider
  • MFA must be performed by administrator to gain access to NSX Manager

Which identity deployments would meet the customer’s requirements? (Choose the best answer.)

Options:

A.

NSX Manager OAuth 2.0 registered to a 3-node Active Directory Federation Services cluster.

B.

NSX Manager OAuth 2.0 registered to a 2-node VMware Identity Manager cluster.

C.

NSX Manager OAuth 2.0 registered to a 2-node Active Directory Federation Services cluster

D.

NSX Manager OAuth 2.0 registered to a 3-node VMware Identity Manager cluster.

Buy Now
Question # 7

An NSX-T Architect is working in a brownfield environment with 4 ESXi hosts. These constraints were documented:

  • new servers cannot be purchased
  • North/South bandwidth must be guaranteed
  • Top-of-Rack switches have additional uplinks

Which three recommendations should the architect implement? (Choose three.)

Options:

A.

Remove one of the ESXi hosts and install a bare-metal Edge.

B.

Use a resource pool for production workloads.

C.

Use a resource pool to deploy the Edge nodes on.

D.

Recommend obtaining 2 new physical NICs for the servers.

E.

Install Edge nodes on a separate cluster.

Buy Now
Question # 8

Which type of design includes vendor models, host names, IP Addresses, port connections, logical unit number sizes, and number of CPUs? (Choose the best answer.)

Options:

A.

Physical Design

B.

Conceptual Design

C.

High-Level Design

D.

Logical Design

Buy Now
Question # 9

An architect is helping an organization with the Conceptual Design of an NSX-T Data Center solution.

Which risk is documented by an architect? (Choose the best answer.)

Options:

A.

The security team has a firewall communication matrix documented.

B.

The team is not trained for NSX-T but have a very strong experience with vSphere.

C.

Open communication between different application tiers is not allowed.

D.

Aggregate N-S throughput at any given time should be at least 10G.

Buy Now
Question # 10

An architect is helping an organization with the Conceptual Design of an NSX-T Data Center solution.

This information was gathered by the architect during the Discover Task of the Engagement Lifecycle:

  • There are applications which use IPv6 addressing.
  • Network administrators are not familiar with NSX-T Data Center solutions.
  • Hosts can only be configured with two physical NICs.
  • There is an existing management cluster to deploy the NSX-T components.
  • Dynamic routing should be configured between the physical and virtual network.
  • There is a storage array available to deploy NSX-T components.

Which risk was documented by the architect? (Choose the best answer.)

Options:

A.

Network administrators are not familiar with NSX-T Data Center solutions.

B.

Dynamic routing should be configured between the physical and virtual network.

C.

There are applications which use IPv6 addressing.

D.

There is a storage array available to deploy NSX-T components.

Buy Now
Question # 11

An architect is helping an organization with the Logical Design of an NSX-T Data Center solution.

This information was gathered during the assessment:

  • There must be a performance based SLA for East – West traffic.

Which two key performance features should the architect recommend? (Choose two.)

Options:

A.

Configure N-VDS enhanced Data Path

B.

Install advanced Edge pNIC Features

C.

Setup RSS to leverage multiple cores

D.

Leverage DPDK drivers

E.

Enable GENEVE Offload

Buy Now
Exam Code: 3V0-42.20
Exam Name: Advanced Design VMware NSX-T Data Center
Last Update: Feb 22, 2025
Questions: 57
3V0-42.20 pdf

3V0-42.20 PDF

$25.5  $84.99
3V0-42.20 Engine

3V0-42.20 Testing Engine

$28.5  $94.99
3V0-42.20 PDF + Engine

3V0-42.20 PDF + Testing Engine

$40.5  $134.99